Specifiche
prodotto:
Multi-Application Data Loggers 1016/1416
General
|
Size |
3.4 x 2.1 x 1" (85 x 59 x 26mm); |
|
Operating Range |
-95¡C to +70¡C (-139¡F to 158¡F) |
|
Interfaces |
RS-232 serial
port; Ethernet; PoE & WiFi interfaces available |
|
Mounting |
Magnetic strips;
3M Dual LockªFasteners; Snap-in connector locks provide secure probe
connections |
|
PC Software |
|
|
Clock |
Accuracy: ±1
min./month at 0¡C to +50¡C (+32¡F to +122¡F) |
|
Electromagnetic Interference |
Meets FCC Part
15 for digital devices; meets CE requirements for radiated
emissions, electrostatic discharge, and radiated susceptibility. |
|
Power Source |
Internal lithium battery with life of 10 years at 1 minute sampling rate. |
Multi-Application Temperature Recorder Accuracy
|
Sensor |
Calibrated |
Resolution |
One year Accuracy |
|
V Range External Probe |
-90¡C to +50¡C (-130¡F to +122¡F) |
0.01¡C at +25¡C (0.02¡F at +77¡F) |
±0.35¡C over
-90¡C to +50¡C (±0.63¡F over
-130¡F to +122¡F) |
Memory
|
Memory Type |
Non-volatile EEROM |
|
Data Sample Capacity |
1016 - 68,600
16-bit samples (2 channels) 1014 - 101,375
16-bit samples (4 channels) |
|
Memory Modes |
User-selectable:
Wrap when memory full (FIFO) or Stop when memory full. User-selectable start
time and (for VL series) stop time. |
|
Memory Protection |
Data retention
> 20 years backup without power. |
|
Sampling Rates |
User-selectable
from once every minute to once a day. |
|
Recording Span |
Recording span
depends on sample interval selected and number of channels enabled. Chart
below details typical sampling rates and length of time logger will retain
data in memory before wrapping around or stopping (see Memory Modes). |
Recording Span: 1016 - 22V
|
Sample Interval |
1 Channel |
2 Channels |
|
1 minute |
1.5 Months |
23.8 Days |
|
5 minutes |
7.6 Months |
3.8 Months |
|
15 minutes |
1.9 Years |
11.5 Months |
|
1 hour |
7.8 Years |
3.9 Years |
Recording Span: 1416 - 44V
|
Sample Interval |
1 channel |
2 channels |
3 channels |
4 channels |
|
1 minute |
2.3 Months |
1.1 Months |
23.5 Days |
17.6 Days |
|
5 minutes |
11.3 Months |
5.6 Months |
3.7 Months |
2.8 Months |
|
15 minutes |
2.8 Years |
1.4 Years |
11.3 Months |
8.5 Months |
|
1 hour |
11.5 Years |
5.7 Years |
3.8 Years |
2.8 Years |
Temperature Probes: Stainless
or Teflon Tip
|
Sensor |
Operating Range |
Color Code |
Sensor Tip |
Probe Length |
Cable Construction |
|
V Range external probe:EPT-23N-XXV |
-95¡C to +70¡C (-139¡F to +158¡F) |
Blue |
Stainless Steel Diameter: 3.2 mm (1.8") length: 38mm (1.5") |
XX denotes
length of probe in feet. 3 m(10') and 7.6
m (25') probes available. |
2mm (0.07") Diameter Teflon coated cable |
|
V Range external probe:EPT-22W-XXV |